Review



precellys homogenizer  (Bertin Technologies)


Bioz Verified Symbol Bertin Technologies is a verified supplier
Bioz Manufacturer Symbol Bertin Technologies manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 98

    Structured Review

    Bertin Technologies precellys homogenizer
    Precellys Homogenizer, supplied by Bertin Technologies, used in various techniques. Bioz Stars score: 98/100, based on 1433 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/precellys+evolution+homogenizer/PRECELLYS+EVOLUTION+HOMOGENIZER/pm42299507-41-66-68
    Average 98 stars, based on 1433 article reviews
    precellys homogenizer - by Bioz Stars, 2026-10
    98/100 stars

    Images

    Related Articles

    Concentration Assay:

    Article Title: Old nodes, new tricks: optimized methods for chronic wasting disease prion detection in preserved retropharyngeal lymph nodes.
    Article Snippet: .. Tissue preparation for fresh-frozen RPLNs We weighed fresh-frozen RPLNs to 50 mg (± 5 mg) and transferred them to 2-mL reinforced lysing tubes with 2.8- mm ceramic beads (Omni International), which then were filled with 1× PBS to create a 10% weight/volume concentration and homogenized (Precellys Evolution homogenizer; Bertin Technologies) at 7500 rpm with 4 cycles of 30 s on, 30 s off, repeated twice. ..

    Article Title: Constitutive zeaxanthin accumulation affects photosynthetic activity and non-photochemical quenching in Chlorella vulgaris.
    Article Snippet: .. Genomic DNA extraction was performed starting from 100 mL culture at a concentration of 5 ⋅107 cell mL− 1 by the cetyltrimethylammonium bromide (CTAB) extraction method (Lutz et al., 2011) after a pre-treatment with glass beads using a Precellys Evolution homogenizer (Bertin Technologies SAS, France). .. DNA purity was measured using a Nanodrop One Spectrophotometer (Thermo Fisher Scientific, Italy), while the integrity was assessed by capillarity electrophoresis with a 4150 Tape station (Agilent Technologies, US).

    DNA Extraction:

    Article Title: Constitutive zeaxanthin accumulation affects photosynthetic activity and non-photochemical quenching in Chlorella vulgaris.
    Article Snippet: .. Genomic DNA extraction was performed starting from 100 mL culture at a concentration of 5 ⋅107 cell mL− 1 by the cetyltrimethylammonium bromide (CTAB) extraction method (Lutz et al., 2011) after a pre-treatment with glass beads using a Precellys Evolution homogenizer (Bertin Technologies SAS, France). .. DNA purity was measured using a Nanodrop One Spectrophotometer (Thermo Fisher Scientific, Italy), while the integrity was assessed by capillarity electrophoresis with a 4150 Tape station (Agilent Technologies, US).

    Extraction:

    Article Title: Constitutive zeaxanthin accumulation affects photosynthetic activity and non-photochemical quenching in Chlorella vulgaris.
    Article Snippet: .. Genomic DNA extraction was performed starting from 100 mL culture at a concentration of 5 ⋅107 cell mL− 1 by the cetyltrimethylammonium bromide (CTAB) extraction method (Lutz et al., 2011) after a pre-treatment with glass beads using a Precellys Evolution homogenizer (Bertin Technologies SAS, France). .. DNA purity was measured using a Nanodrop One Spectrophotometer (Thermo Fisher Scientific, Italy), while the integrity was assessed by capillarity electrophoresis with a 4150 Tape station (Agilent Technologies, US).

    Disruption:

    Article Title: Exercise-associated and metabolic effects of Cimicifuga racemosa extract Ze 450 in a high-fat diet model in female rats.
    Article Snippet: .. Total RNA was extracted using TRIzolTM reagent (Thermo Fisher Scientific, USA) and homogenized by bead-based disruption using a Precellys® Evolution homogenizer (Bertin Technologies, France). .. Visceral adipose tissue was processed in 0.5 mL screw-cap tubes containing 1.4 mm ceramic beads (VWR International, Germany), whereas liver tissue was homogenized using 2.8 mm ceramic beads (VWR International).



    Similar Products

    98
    Bertin Technologies precellys homogenizer
    Precellys Homogenizer, supplied by Bertin Technologies, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/precellys+evolution+homogenizer/PRECELLYS+EVOLUTION+HOMOGENIZER/pm42299507-41-66-68
    Average 98 stars, based on 1 article reviews
    precellys homogenizer - by Bioz Stars, 2026-10
    98/100 stars
      Buy from Supplier

    98
    Bertin Technologies precellys evolution homogenizer
    Precellys Evolution Homogenizer, supplied by Bertin Technologies, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/precellys+evolution+homogenizer/PRECELLYS+EVOLUTION+HOMOGENIZER/pm42263257-299-13-16
    Average 98 stars, based on 1 article reviews
    precellys evolution homogenizer - by Bioz Stars, 2026-10
    98/100 stars
      Buy from Supplier

    97
    Bertin Technologies precellys evolution touch
    Precellys Evolution Touch, supplied by Bertin Technologies, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/precellys+evolution+homogenizer/PRECELLYS+EVOLUTION+TOUCH+HOMOGENIZER/bio_rxiv__64898__2026__05__29__728673-419-7-10
    Average 97 stars, based on 1 article reviews
    precellys evolution touch - by Bioz Stars, 2026-10
    97/100 stars
      Buy from Supplier

    97
    Bertin Technologies precellys evolution touch homogenizer
    Precellys Evolution Touch Homogenizer, supplied by Bertin Technologies, used in various techniques. Bioz Stars score: 97/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/precellys+evolution+homogenizer/PRECELLYS+EVOLUTION+TOUCH+HOMOGENIZER/pmc13053984-40-6-10
    Average 97 stars, based on 1 article reviews
    precellys evolution touch homogenizer - by Bioz Stars, 2026-10
    97/100 stars
      Buy from Supplier

    98
    Bertin Technologies precellys evolution tissue homogeniser
    Schematic representation of the relationship between C-laurdan emission and monolayer fluidity (A); Plot of GP distributions (B) and GP values versus mean diameter (C) in MBs prepared by tissue <t>homogeniser</t> Capmix and sonication. GP distributions refer to MBs in the clinical range (1–5 μm), shown in grey. Different point shapes (circle, square and diamond) and line styles (solid, dashed, dotted) represent different batches.
    Precellys Evolution Tissue Homogeniser, supplied by Bertin Technologies, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/precellys+evolution+homogenizer/PRECELLYS+EVOLUTION+HOMOGENIZER/pmc13191645-54-16-20
    Average 98 stars, based on 1 article reviews
    precellys evolution tissue homogeniser - by Bioz Stars, 2026-10
    98/100 stars
      Buy from Supplier

    Image Search Results


    Schematic representation of the relationship between C-laurdan emission and monolayer fluidity (A); Plot of GP distributions (B) and GP values versus mean diameter (C) in MBs prepared by tissue homogeniser Capmix and sonication. GP distributions refer to MBs in the clinical range (1–5 μm), shown in grey. Different point shapes (circle, square and diamond) and line styles (solid, dashed, dotted) represent different batches.

    Journal: Ultrasonics Sonochemistry

    Article Title: Comparison of ultrasound contrast agent production by sonication and mechanical agitation

    doi: 10.1016/j.ultsonch.2026.107875

    Figure Lengend Snippet: Schematic representation of the relationship between C-laurdan emission and monolayer fluidity (A); Plot of GP distributions (B) and GP values versus mean diameter (C) in MBs prepared by tissue homogeniser Capmix and sonication. GP distributions refer to MBs in the clinical range (1–5 μm), shown in grey. Different point shapes (circle, square and diamond) and line styles (solid, dashed, dotted) represent different batches.

    Article Snippet: Then, vial was inserted into a custom made insert ( ) which was placed in a Precellys Evolution tissue homogeniser (Bertin technologies, Maryland, USA).

    Techniques: Sonication

    Effect of agitation frequency (A–C) and agitation time (B–D) on concentration (A–B) and mean size (C–D) of MBs produced with the tissue homogeniser.

    Journal: Ultrasonics Sonochemistry

    Article Title: Comparison of ultrasound contrast agent production by sonication and mechanical agitation

    doi: 10.1016/j.ultsonch.2026.107875

    Figure Lengend Snippet: Effect of agitation frequency (A–C) and agitation time (B–D) on concentration (A–B) and mean size (C–D) of MBs produced with the tissue homogeniser.

    Article Snippet: Then, vial was inserted into a custom made insert ( ) which was placed in a Precellys Evolution tissue homogeniser (Bertin technologies, Maryland, USA).

    Techniques: Concentration Assay, Produced